Share To Facebook
DIV24-02
    產品名稱 : DIV24-02
    產品型號 : DIV24-02
    產品介紹

    DATA SHEET

    Model No. : DIV24-02
    Description : 2~3GHz 2-WAY POWER DIVIDER
    Date : 2009/10/13
    Rev : 1
    1. OVERVIEW & SPECIFICATIONS

      Electrical Specifications:

      Frequency Range : 2000~ 3000 MHz
      Insertion loss : ≤ 1.8 dB
      Impedance : 50Ω ± 5Ω
      VSWR : ≤ 2.0
      Isolation : ≤ 20 dB
      Power Handling : 10 watts
      Phase unbalance ±2 degrees max

      Mechanical Specifications:

      Connector : N Female
      Operation Temp. : -30℃ ~ +60℃
      Material : aluminum
      Dimension (L*W*H) : 89.59*50.65*22mm

      3D Illustration

    2. TESTING CONDITION

      • 2.1 TEST SETUP
        VSWR measurement (S11): Use ROHDE & SCHWARZ ZV8 Network Analyzer with Harbour RG-142 coaxial cable: 1000mm length in free space.
      • 2.1.1 VSWR
        The table as below summarizes concern about Return loss measurement according to The frequency band is based on FWS design. The detail be shown as appendix that is from ROHDE & SCHWARZ ZV8 Network Analyzer
        VSWR Performance
        Freq(MHz) 2000 2500 3000
        Free space 1.3 1.2 1.1
      • 2.1.2 ISOLATION MEASUREMENT
        The isolation of the power divider was measured by ROHDE & SCHWARZ ZV8 Network Analyzer. The way to measured isolation is connect output ports and the other ports mount with 50 ohm matches respectively. The table as below summarizes concern about isolation measurement according to The frequency band is based on FWS design.
             isolation Performance
        Freq(MHz) 2000 2500 3000
        Isolation(dB) -31.8 -38.9 -21.4
      • 2.1.3 INSERTION LOSS MEASUREMENT
        The insertion loss of the power divider was measured by ROHDE & SCHWARZ ZV8 Network Analyzer. The way to measured insertion loss is connect input and output port and the other ports mount with 50 ohm matches respectively. The table as below compared with S12 and S13 insertion loss measurement according to The frequency band is based on FWS design. The table as below have already reduced 3 dB of measurement.
               Insertion loss Performance
        Freq(MHz) 2000 2500 3000
        Insertion(S12) dB -1.7 -1.3 -1.2
        Freq(MHz) 2000 2500 3000
        Insertion(S13) dB -1.5 -1.2 -1.2
      • 2.1.4 PHASE MEASUREMENT
        The method to measured phase variety of power divider is connect input and output port with ROHDE & SCHWARZ ZV8 Network Analyzer. Other ports mounted 50 ohm matches respectively. The table as below compared with S12 and S13 phase measurement according to The frequency band is based on FWS design.
               Performance
        Freq(MHz) 2000 2500 3000
        Degree(S12) 109.6 -9.6 54.6
        Freq(MHz)200025003000
        Degree(S13) 108.1 -8.7 56.3
    3. APPENDIX

      • 3.1 RETURN LOSS & VSWR

        RETURN LOSS

        SWR

      • 3.2 ISOLATION

      • 3.3 INSERTION LOSS

        S12

        S13

      • 3.4 PHASE MEASUREMENT

        S12

        S13